Products

Product Center Overview

Technical Solutions Across 4 Key Industries

iMeter 7
  • Advanced Power Quality Monitor
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed. 2 Class A Certified
  • DIN144 (138x138mm Cutout)
  • Colour TFT LCD Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 2GB On-board Memory
  • Modbus RTU, Modbus TCP, HTTP, SNTP, SMTP, FTP, Ethernet Gateway, Optional IEC61850
  • 1xEthernet, 2xRS-485
  • 8xDI, 4xRO, 2xDO
PMC-509
  • Multi-Circuit Multifunction Monitor
  • Class 0.5S Revenue Metering with Bi-directional Measurements
  • 35mm DIN Rail, 180×94.5×57.5mm
  • Backlit B&W LCD Display
  • Demands and Event Log
  • 8MB On-board Memory
  • Modbus RTU
  • 1xRS-485
  • 4xDI, Optional 3xRTD
PMC-330
  • Three-Phase Energy Meter
  • IEC 62053-21 Class 1 (80A Direct Input)
  • 35mm DIN Rail, 126x90x75mm
  • B&W LCD Display
  • Demands & TOU, Max/Min Log and Event Log
  • Modbus RTU
  • 1xRS-485
  • 1xSS Pulse Output, Optional 2xDO, 2xDI
PMC-43M
  • Three-Phase Multifunction Meter
  • IEC62053-21 Class 1
  • DIN80 (76x76mm Cutout)
  • Backlit B&W LCD Display
  • AC V&I, Power & Energy and Event Log
  • Modbus RTU, Metasys N2 and BACnet MS/TP
  • 1xRS-485
  • 2xDI, Optional 1xAO
PMC-53M
  • Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit B&W LCD Display
  • Harmonics, Demands and Event Log
  • Modbus RTU, Metasys N2 and BACnet MS/TP
  • 1xRS-485
  • 2xDI, 2xDO, Optional 2xSS Pulse Outputs
PMC-630A/B/C
  • Advanced Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.2S
  • DIN96 (92x92mm Cutout)
  • Backlit B&W LCD Display
  • Harmonics, Demands, Max/Min Log, Data Log and Event Log
  • I Residual Monitoring, PQ Event Waveform Capture
  • 1xRS-485 or 2xRS-485 or 1xProfibus-DP
  • 6xDI, 2xDO, Optional 3rd & 4th DO, 1xAO, 2xSS Pulse Outputs
PMC-630E
  • Advanced Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.2S
  • DIN96 (92x92mm Cutout)
  • Backlit B&W LCD Display
  • Harmonics, Demands, Max/Min Log, Waveform Log, Data Log, Energy Log and Event Log
  • 2MB On-board Memory
  • 2xRS-485 or 1xRS-485 + 1xEthernet
  • 6xDI, 3xDO
PMC-53M-E
  • Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • High-contrast LED Display
  • Harmonics, Demands, Max/Min Log, Setpoint Alarms and Event Log
  • Modbus RTU
  • 1xRS-485
  • Optional 4xDI, 2xDO
PMC-D721MD
  • Low-Cost DC Multifunction Meter
  • Class 0.5 kWh Compliant
  • DIN72 (68x68mm Cutout)
  • Backlit B&W LCD Display
  • DC V&I, kW and Event Log
  • Modbus RTU
  • 1xRS-485
  • 2xDI, 2xSS Pulse Output
PMC-512-A
  • AC Multi-Circuit Power Monitor
  • IEC 62053-21 Class 1
  • 126x90x65mm
  • Backlit B&W LCD Display
  • 12×1-Phase or 4×3-Phase Sub-Meters
  • Harmonics, Demands, Data Log and Event Log
  • Modbus RTU
  • 2xRS-485
  • 12xDI, 1xDO
PMC-592
  • Multi-Circuit Power Monitor
  • IEC 62053-22 Class 0.5S for Mains, IEC62053-21 Class 1 for Branches
  • 260.5x154x55.5mm
  • LED Indicators, Optional Touch Screen HMI
  • 2 Mains Inputs each with 3xV & 4xI, 84 Branch Circuits with CT-Strip Accessories
  • Harmonics, Demands, Waveform Log, Dip/Swell Log and Event Log
  • 1GB On-board Memory
  • Modbus RTU/TCP, SNMP, HTTP, SMTP, SNTP
  • 1xEthernet, 2xRS-485
  • 2xDI, 2xDO, 1xRTD
PMC-D726M
  • Low-Cost Three-Phase Multifunction Meter
  • IEC62053-21 Class 1
  • DIN72 (68x68mm Cutout)
  • Backlit B&W LCD / High-contrast LED Display
  • Harmonics, Demands & TOU and Event Log
  • Modbus RTU
  • 1xRS-485
  • Optional 2xDI, 2xDO,1xAO, 2xSS Pulse Output
Customization Process Guide

From Concept to Mass Production

img1
01
Requirement Analysis & Solution Design
We go beyond order-taking by analyzing your application (PV, storage, EV charging) to define key parameters—turns ratio, accuracy, linearity, and dimensions—while optimizing integrator matching and anti-interference design for Rogowski coils.
img3
02
Rapid Product Prototyping
Once the plan is confirmed, we initiate rapid prototyping. Utilizing our modular core inventory and flexible winding processes, we produce functional samples within 15-20 days, allowing you to proceed with circuit testing and validation ASAP.
case-img4
03
Rigorous Testing & Validation
Samples undergo strict functional and environmental testing, including ratio and phase error calibration, as well as withstand voltage, temperature rise, and EMC tests to meet IEC 61869 and application requirements.
img2
04
Scalable Mass Production
After approval, we move to mass production using automated winding and epoxy casting lines, ensuring consistent magnetic performance and insulation reliability, with monthly capacity over 500,000 units.
gallery-img3
05
Final QC & Global Delivery
We perform AQL sampling or 100% inspection before shipment to ensure zero defects in appearance and performance. Familiar with export packaging standards, we provide shock-proof and moisture-proof packing for on-time global delivery.

Trusted Quality, Proven Performance

Committed to Deliver Reliable Sensing Solutions

Get in Touch
Contact our team anytime for product inquiries, technical support, or project consultation. We are ready to assist you with responsive service and professional guidance.

About Us

Jiangyin Yucheng Electric, Jiangsu, China, makes current sensors and smart meters for global power and industrial applications, offering reliable, high-accuracy, standards-compliant solutions.

Contact Info

No.5 Tongxin Road, Qingyang Town,Jiangsu,China