Product Center Overview

Technical Solutions Across 4 Key Industries

PMC-53M-A
  • Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit B&W LCD Display
  • Harmonics, Demands, Max/Min Log, Setpoint Alarms and Event Log
  • Modbus RTU
  • 1xRS-485
  • Optional 4xDI, 2xDO
PMC-512-J
  • DC Multi-Circuit Insulation Monitor
  • 126x90x65mm
  • LED Indicators, Optional Touch Screen HMI
  • 21 Residual Current measurements and Insulation Resistance Calculation
  • Data Log and Event Log
  • Modbus RTU
  • 2xRS-485
  • 2xDI, 2xDO, 1xAI
PMC-512-D
  • DC Multi-Circuit Power Monitor
  • Class 0.5 (Main Unit only), Class 1.0 (Hall Effect CT)
  • 126x90x65mm
  • LED Indicators, Optional Touch Screen HMI
  • One Mains, 12 Branches
  • Demands, Data Recorder and Event Log
  • Modbus RTU
  • 2xRS-485
  • 13xDI, 1xDO, 1xAI
PMC-660
  • Advanced Utility Power Quality Analyzer
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed.2 Class A Certified
  • DIN192 (186x186mm Cutout)
  • Colour TFT LCD Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 4GB On-board Memory
  • Modbus RTU, Modbus TCP, HTTP, SNTP, SMTP, FTP, Ethernet Gateway, Optional IEC61850
  • 2xEthernet, Optional 2xRS-485
  • 8xDI, 4xRO, 4xDO
PMC-670
  • Advanced C&I Power Quality Analyzer
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed.2 Class A Certified
  • DIN144 (138x138mm Cutout)
  • Colour TFT LCD Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 2GB On-board Memory
  • Modbus RTU, Modbus TCP, HTTP, SNTP, SMTP, FTP, Ethernet Gateway, Optional IEC61850
  • 1xEthernet, 2xRS-485
  • 8xDI, 4xRO, 2xDO
PMC-680i
  • Advanced Utility Power Quality Analyzer
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed.2 Class A Certified
  • DIN192 (186x186mm Cutout)
  • Colour TFT LCD Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 4GB On-board Memory
  • Modbus RTU, Modbus TCP, HTTP, SNTP, SMTP, FTP, Ethernet Gateway, Optional IEC61850
  • 2xEthernet, Optional 2xRS-485
  • 8xDI, 4xRO, 4xDO
PMC-690
  • Hand-Held Power Quality Analyzer
  • IEC 62053-22 Class 0.5S, IEC61000-4-30 Ed.2 Class A Compliant
  • 252x160x59mm
  • Colour TFT LCD Display
  • Harmonics, Demands, Max/Min Log, Waveform Log and Event Log
  • 16GB Removeable SD Card
  • Modbus RTU, SNTP, IEC61850
  • 1xEthernet, 1xUSB port
  • Free DiagSys Software for Analysis
iMeter 7
  • Advanced Power Quality Monitor
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed. 2 Class A Certified
  • DIN144 (138x138mm Cutout)
  • Colour TFT LCD Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 2GB On-board Memory
  • Modbus RTU, Modbus TCP, HTTP, SNTP, SMTP, FTP, Ethernet Gateway, Optional IEC61850
  • 1xEthernet, 2xRS-485
  • 8xDI, 4xRO, 2xDO
PMC-509
  • Multi-Circuit Multifunction Monitor
  • Class 0.5S Revenue Metering with Bi-directional Measurements
  • 35mm DIN Rail, 180×94.5×57.5mm
  • Backlit B&W LCD Display
  • Demands and Event Log
  • 8MB On-board Memory
  • Modbus RTU
  • 1xRS-485
  • 4xDI, Optional 3xRTD
PMC-330
  • Three-Phase Energy Meter
  • IEC 62053-21 Class 1 (80A Direct Input)
  • 35mm DIN Rail, 126x90x75mm
  • B&W LCD Display
  • Demands & TOU, Max/Min Log and Event Log
  • Modbus RTU
  • 1xRS-485
  • 1xSS Pulse Output, Optional 2xDO, 2xDI
PMC-43M
  • Three-Phase Multifunction Meter
  • IEC62053-21 Class 1
  • DIN80 (76x76mm Cutout)
  • Backlit B&W LCD Display
  • AC V&I, Power & Energy and Event Log
  • Modbus RTU, Metasys N2 and BACnet MS/TP
  • 1xRS-485
  • 2xDI, Optional 1xAO
PMC-53M
  • Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit B&W LCD Display
  • Harmonics, Demands and Event Log
  • Modbus RTU, Metasys N2 and BACnet MS/TP
  • 1xRS-485
  • 2xDI, 2xDO, Optional 2xSS Pulse Outputs
Customization Process Guide

From Concept to Mass Production

img1
01
Requirement Analysis & Solution Design
We go beyond order-taking by analyzing your application (PV, storage, EV charging) to define key parameters—turns ratio, accuracy, linearity, and dimensions—while optimizing integrator matching and anti-interference design for Rogowski coils.
img3
02
Rapid Product Prototyping
Once the plan is confirmed, we initiate rapid prototyping. Utilizing our modular core inventory and flexible winding processes, we produce functional samples within 15-20 days, allowing you to proceed with circuit testing and validation ASAP.
case-img4
03
Rigorous Testing & Validation
Samples undergo strict functional and environmental testing, including ratio and phase error calibration, as well as withstand voltage, temperature rise, and EMC tests to meet IEC 61869 and application requirements.
img2
04
Scalable Mass Production
After approval, we move to mass production using automated winding and epoxy casting lines, ensuring consistent magnetic performance and insulation reliability, with monthly capacity over 500,000 units.
gallery-img3
05
Final QC & Global Delivery
We perform AQL sampling or 100% inspection before shipment to ensure zero defects in appearance and performance. Familiar with export packaging standards, we provide shock-proof and moisture-proof packing for on-time global delivery.

Trusted Quality, Proven Performance

Committed to Deliver Reliable Sensing Solutions

Get in Touch
Contact our team anytime for product inquiries, technical support, or project consultation. We are ready to assist you with responsive service and professional guidance.

About Us

Jiangyin Yucheng Electric, Jiangsu, China, makes current sensors and smart meters for global power and industrial applications, offering reliable, high-accuracy, standards-compliant solutions.

Contact Info

No.5 Tongxin Road, Qingyang Town,Jiangsu,China