Hall Current Sensor:

Wide Range, High Stability

Current Precision

Signal Stability

Rapid Response

High Precision Hall Current Sensor

Accurately measures DC, AC, and pulse currents, suitable for a wide range of industrial and commercial applications.

 

Fully insulated primary and secondary circuits provide reliable safety and protection against electrical interference.

 

Compact, lightweight design ensures easy installation and seamless integration into control panels and automated systems.

Application scenarios

Motor Control

Industrial motor control system

Power Distribution

High and low voltage distribution cabinet & power distribution room

Renewable Integration

PV & wind power new energy grid connection

Energy Monitoring

Building & park energy consumption metering management

Automation Control

Inverter and automatic industrial control equipment

Grid Protection

Substation and power relay protection

Experience & Certification

With over ten years of industry experience, our products meet international quality standards. Certified with ISO9001 and RoHS, we ensure reliable, safe, and environmentally friendly solutions for all applications.

Electrical Parameter Characteristics(Ta=25°C)

Maximum Withstand Voltage
0.66kV
Rated Primary Current
0A ~ 300kA
Rated Secondary Output
With integrator:
4V / 1A (AC) or 4–20mA (DC)
Without integrator:
100mV/kA, 50mV/kV
Accuracy
1%

10%-100% Accuracy
5% (without integrator) 1% (with integrator, 45-65HZ)

Phase error
W+1°(45-65HZ) W+10°(20KHZ)
Auxiliary Power Supply
±12V, 24V, 5V DC or 220V AC
Power Consumption
≤10W
Operating Frequency
1Hz – 1MHz
Note: Other specifications can be customized according to customer requirements.
 
Performance Index
10%-100% Accuracy
5% (without integrator) 1% (with integrator, 45-65HZ)
Phase error
W±1° (45-65HZ) W±10°(20KHZ)
10%-100% Linearity
0.50%
Integrator power supply
7-30VDC
Response bandwidth
1HZ-1MHZ
Coil section diameter
W7.5、W10、W12mm or Custom made
Coil length
W2M or Custom made
Use altitude
W2000M
Protection level
IP65
Texture of material
Silicon rubber
Secondary lead
Shielded wire,length customized
Compressive strength
2KVAC/min
Insulation resistance
DC500V/100MQ
Parameter DescriptionSymbolUnitTest ConditionMinStandardMax
Power Supply VoltageVCCV@DC+4.75V+5V+5.25V
Power Consumption CurrentICmA@IPN-15-
Rated OutputVOUTV@RL=10K T=25℃-VOE±1-
Static Zero OutputVOEV@IP=0A,T=25℃2.492.52.51
Hysteresis VoltageVOMV--±0.01-
Load ResistanceRLΩ@DC+5V, IPN10K--
AccuracyXG%@IPN,T=25℃-±1-
Linearityε L%@IPN,T=25℃-±1-
Current Following Accuracydi/dtA/μs-100--
Response TimeTRμs@90%IPN--5
Zero Output Temperature DriftTCVOEmV/℃@-40℃~+85℃-±1.0-
Rated Output Temperature DriftTCVout%/℃@-40℃~+85℃-±0.1-
Operating BandwidthBWKHz@DC-20-
Operating Temperature RangeTA--40℃-+85℃
Storage Temperature RangeTS--45℃-+105℃
Withstand VoltageVdV@AC50/60Hz, 1 minute-3000-
Insulation Resistance-Ω@DC500V1000M--

Note:  Other specifications can be customized according to the specific requirements of customers.

Outline and Installation Dimensions

  • General Tolerance:+1 mm
  • Other Tolerances Standard :GB/T 1804-2000-M
Model No. Rated Current IPN(A) Maximum Measuring Range IPM(A)
YCV50EKA51 50 110
YCV100EKA51 100 220
YCV200EKA51 200 440
YCV300EKA51 300 660
YCV400EKA51 400 880
YCV500EKA51 500 900
YCV50EKA52 50 55
YCV100EKA52 100 110
YCV200EKA52 200 220
YCV300EKA52 300 330
YCV400EKA52 400 440
YCV500EKA52 500 550

Usage Instructions and Precautions

● Refer to the current direction arrow in the structural diagram to connect the current correctly, and pay attention to the forward and reverse directions of the current passing through the sensor.

● Strictly follow the functional pin definitions marked in the structural diagram forwiring (Note: Incorrect wiring may cause damage to the sensor).

● The above specifications are for standard parameter products; products can becustomized according to customer requirements.

Certificates & Accreditation

We proudly showcase our enterprise honors and management system certifications, reflecting our commitment to quality, reliability, and industry excellence. These certificates demonstrate our dedication to maintaining high standards in all aspects of our operations.

           

Equipment Image Information

Explore detailed images of our equipment, showcasing the advanced technology, precision engineering, and robust build quality that support our high-performance operations. Each image is accompanied by informative descriptions to provide a comprehensive understanding of our machinery.

Fully automated sensor core continuous tunnel heat treatment furnace production line

Contact Us

8 fully automatic high-speed & 14 continuous precision stamping presses

Contact Us

24 Fully Automatic Magnetic Core Winding Machines

Contact Us

6 Fully Automated Sensor Core Continuous Tunnel Heat Treatment Furnace Production Lines

Contact Us

6 Fully Automatic Testing & Sorting Machines

Contact Us

2 Solenoid (Tripper) Manufacturing Lines

Contact Us

6 Fully Automatic Magnetic Core Packaging Machines

Contact Us

260 Fully Automatic Winding Machines

Contact Us

8 fully automatic current transformer potting machines

Contact Us

2 Current Transformer Assembly Lines

Contact Us

Winding Production Line Workshop 2

Contact Us

6 Fully Automatic Magnetic Core Testing Machines

Contact Us

Large Magnetic Core Continuous Furnace

Contact Us

Strip Slitting & Cutting Production Line

Contact Us

5 Fully Automatic Ultra-Microcrystalline Heat Treatment Lines

Contact Us

Technology Dept / R&D Center / Material Testing

Discover our Technology Department, R&D Center, and Material Testing facilities through detailed images. These showcase our commitment to innovation, rigorous research, and precise material analysis, ensuring the highest quality and reliability in every product we develop.

View More

Roche Coil Transformer (flexible Opening Transformer) – CTLS4

A flexible Rogowski coil current sensor designed for accurate AC current measurement in large, irregular, or hard-to-access conductors. It features an openable structure for easy installation and is suitable for both temporary and long-term monitoring applications.

Read More »

Roche Coil Transformer (flexible Opening Transformer) – CTLS3

A flexible Rogowski coil current sensor designed for accurate AC current measurement in large, irregular, or hard-to-access conductors. It features an openable structure for easy installation and is suitable for both temporary and long-term monitoring applications.

Read More »

Roche Coil Transformer (flexible Opening Transformer) – CTLS2

A flexible Rogowski coil current sensor designed for accurate AC current measurement in large, irregular, or hard-to-access conductors. It features an openable structure for easy installation and is suitable for both temporary and long-term monitoring applications.

Read More »

Roche Coil Transformer (flexible Opening Transformer) – CTLSX

A flexible Rogowski coil current sensor designed for accurate AC current measurement in large, irregular, or hard-to-access conductors. It features an openable structure for easy installation and is suitable for both temporary and long-term monitoring applications.

Read More »

About Us

Jiangyi Yucheng Electric, Jiangsu, China, makes current sensors and smart meters for global power and industrial applications, offering reliable, high-accuracy, standards-compliant solutions.

Contact Info

No.5 Tongxin Road, Qingyang Town,Jiangsu,China